Skip to content

JASCO JASCO

  • News
  • Events
  • E-Store
  • My Account
  • Contact Us
  • Worldwide
Search
Click to view menu
  • Products
    • Chromatography
      • HPLC
      • RHPLC
      • UHPLC
      • LC-MS
      • Preparative LC
      • Analytical SFC
      • Semi-Preparative SFC
      • Hybrid SFC
      • Fuel Analysis by SFC-FID
      • Preparative SFC
      • Supercritical Fluid Extraction
      • Chromatography Software
    • Molecular Spectroscopy
      • Circular Dichroism
      • High-Throughput CD
      • Vibrational CD
      • Circularly Polarized Luminescence (CPL)
      • Polarimeters
      • FTIR Spectrometers
      • FTIR Microscopy
      • FTIR Portable
      • Raman Microscopy
      • Palmtop Raman Spectrometer
      • Probe Raman
      • UV-Visible/NIR Spectrophotometers
      • UV-Visible/NIR Microscopy
      • Fluorescence Spectrophotometers
      • Film Thickness
      • Spectra Manager™ Suite
    • Refurbished
      • Refurbished HPLC Systems
      • HPLC Switching Valves
      • FTIR Accessories
  • Service
    • Service and Support Plans
    • Service Request Form
  • Applications
  • KnowledgeBase
  • Learning Center
    • Best Practice
      • Circular Dichroism Tips & Tricks for Biological Samples
      • CD Scale Calibration with ACS
      • Fluorescence Tips & Tricks
      • Raman Spectroscopy Tips & Tricks
    • Training Videos
      • ChromNAV
      • SF-NAV
      • Circular Dichroism
      • UV-Visible/NIR
      • Fluorescence
    • Training Seminars
      • Training Registration Form
    • Webinars
    • eBooks
    • Theory
      • Theory of Molecular Spectroscopy
      • Chromatography
  • About Us
    • President’s Message
    • Contact
    • History
    • Careers
  • News
  • Events
  • Worldwide
  • Shop
  • My Account
  • Contact Us

Home / Applications / Gas Analysis System using Full Vacuum FTIR spectrometer (Trace levels of H2O in N2 gas)

  • Industry

  • Technique

Gas Analysis System using Full Vacuum FTIR spectrometer (Trace levels of H2O in N2 gas)

By Carlos Morillo

PDF IconDownload This Application

August 25, 2022

Introduction

Trace gas analysis of low concentration of gases using FTIR spectroscopy with long path length gas cells has been reported previously, however, it is difficult to accurately quantitate gases at low concentrations when the absorption peaks of the target gas overlap with the peaks of atmospheric water vapor or, when the target gas itself is H2O or CO2, which are present in significant amounts in the atmosphere. A key drawback to the use of a vacuum FTIR spectrometer, is that it has not been possible to evacuate the sample chamber with a long path length cell present. The full vacuum gas analysis system introduced in this application note has a special gas cell integrated into the sample chamber, allowing the entire light path to remain under full vacuum with the gas cell in place. This full vacuum model makes it possible to quantitate concentrations of H2O down to 0.1 ppm levels.

Instrument and Measurement

For the measurement, there are separate vacuum lines for evacuation of the FTIR spectrometer and the gas cell, with independent evacuation capability for the separate components. Adding a vacuum gauge to the gas cell makes it possible to control extremely low concentrations of the gas samples.

Full vacuum type FTIR gas analysis system
Figure 1. Full vacuum type FTIR gas analysis system (10 meter cell)

Cell Specification

Cell Type:Multi-pass 'White' cell
Pathlength:10 meter
Cell Body:Stainless steel
Mirror Material:Stainless steel
Mirror Surface:Gold coated
O-Ring:Viton
Window:CaF2
Heating:Possible, max. 100°C
Cell capacity:Approx. 2 L
Gas in/output port:1/4 inch VCR

 

Experimental

The quantitation of a trace levels of water vapor (H2O) in nitrogen gas was made. Water vapor with a concentration of 100 ppm was diluted by monitoring the pressure gauge during dilution of the standard samples with concentrations of 0.0, 0.51, 1.02 and 2.48 ppm. Figure 2 shows the IR spectra of water vapor for each concentration. For the 0 ppm concentration, there was no absorption due to water vapor observed in the spectrum. The calibration curve in Figure 3 was created using the absorption peak at 1653 cm-1.

Figure 2. Expanded region for spectra of low concentration H2O
Figure 3. H2O calibration curve

Conditions

Instrument:FT/IR-6100
Accumulations:200
Resolution:2 cm-1
Apodization:Cosine
Gain:Auto (1)
Aperture:1.8 mm
Scan speed:Auto (4 mm/sec.)
Light source:Standard
Detector:MCT

Keywords

230TR0187-E Gas analysis Full vacuum FTIR spectrometer moisture analysis water analysis H2O analysis

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.

Featured Products:

  • Compact fixed range mid-IR spectrometer with options to extend to the NIR/FIR

    FT/IR-4X

  • Gas Cells

About the Author

Dr. Carlos Morillo received his Post Doc at Advanced Industrial Science & Technology in Fukuoka and was a Research Scientist at Kyushu University in Japan where he lived for several years. Carlos received his Doctor of Engineering from Kyushu University and his Masters and BS from Simon Bolivar University in Caracas Venezuela. He is an Applications Scientist at JASCO.

JASCO Application Note

Gas Analysis System using Full Vacuum FTIR spectrometer (Trace levels of H2O in N2 gas)

Introduction

Trace gas analysis of low concentration of gases using FTIR spectroscopy with long path length gas cells has been reported previously, however, it is difficult to accurately quantitate gases at low concentrations when the absorption peaks of the target gas overlap with the peaks of atmospheric water vapor or, when the target gas itself is H2O or CO2, which are present in significant amounts in the atmosphere. A key drawback to the use of a vacuum FTIR spectrometer, is that it has not been possible to evacuate the sample chamber with a long path length cell present. The full vacuum gas analysis system introduced in this application note has a special gas cell integrated into the sample chamber, allowing the entire light path to remain under full vacuum with the gas cell in place. This full vacuum model makes it possible to quantitate concentrations of H2O down to 0.1 ppm levels.

Instrument and Measurement

For the measurement, there are separate vacuum lines for evacuation of the FTIR spectrometer and the gas cell, with independent evacuation capability for the separate components. Adding a vacuum gauge to the gas cell makes it possible to control extremely low concentrations of the gas samples.

Full vacuum type FTIR gas analysis system
Figure 1. Full vacuum type FTIR gas analysis system (10 meter cell)

Cell Specification

Cell Type:Multi-pass 'White' cell
Pathlength:10 meter
Cell Body:Stainless steel
Mirror Material:Stainless steel
Mirror Surface:Gold coated
O-Ring:Viton
Window:CaF2
Heating:Possible, max. 100°C
Cell capacity:Approx. 2 L
Gas in/output port:1/4 inch VCR

 

Experimental

The quantitation of a trace levels of water vapor (H2O) in nitrogen gas was made. Water vapor with a concentration of 100 ppm was diluted by monitoring the pressure gauge during dilution of the standard samples with concentrations of 0.0, 0.51, 1.02 and 2.48 ppm. Figure 2 shows the IR spectra of water vapor for each concentration. For the 0 ppm concentration, there was no absorption due to water vapor observed in the spectrum. The calibration curve in Figure 3 was created using the absorption peak at 1653 cm-1.

Figure 2. Expanded region for spectra of low concentration H2O
Figure 3. H2O calibration curve

Conditions

Instrument:FT/IR-6100
Accumulations:200
Resolution:2 cm-1
Apodization:Cosine
Gain:Auto (1)
Aperture:1.8 mm
Scan speed:Auto (4 mm/sec.)
Light source:Standard
Detector:MCT

Keywords

230TR0187-E Gas analysis Full vacuum FTIR spectrometer moisture analysis water analysis H2O analysis

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.
28600 Mary’s Court, Easton, MD 21601 USA • (800) 333-5272 • Fax: (410) 822-7526 • jascoinc.com/applications

Close

Designed in Tokyo. TRUSTED globally.

View our support plans

Connect with JASCO

  • Facebook
  • Twitter
  • LinkedIn
  • JASCO Sales
  • 800-333-5272

Receive the latest promotions and special offers

  • This field is for validation purposes and should be left unchanged.
  • Careers
  • Press Kit
  • JASCO Privacy Policy
  • Sitemap
  • Environmental Policy

© , JASCO. All Rights Reserved.