Digital Polarimeter

P-2000 multi-option digital polarimeter for your laboratory needs.

P-2000 Digital Polarimeter

The P-2000 is  a configurable digital polarimeter with many options making it suitable for any application or budgetary requirement. The digital polarimeter may be field upgraded as application requirements change. Options for wavelength filters and source lamps can be used for a wide range of analytical wavelengths from UV-Vis to NIR.

Digital Polarimeter

System Features

Advanced Instrument Control

Two user modes are available including the intelligent remote module (iRM) with a color LCD touch screen and Spectra Manager™ Suite innovative cross-platform spectroscopy software. These control and analysis interfaces allow full system control and data processing. 21 CFR part 11 compliant versions for both Spectra Manager and the iRM are optional.

High Speed, Precision and Accuracy

The P-2000 has a fast response speed up to six degrees per second for reproducible data for each measurement with a resolution of 0.0001°. A wide dynamic range of up to ±90° enables the system to measure chiral compounds over a broad range of concentrations. The sample chamber includes temperature measurement with the current temperature constantly updated and displayed on the control screen.

Accessories

To support a diverse range of sample types and measurements , a variety of accessories and cells include many different options: a wide range of cylindrical cells, a demountable stainless steel cell, Peltier thermostatted cell holder and a monochromator options. Quick-connect fittings with flow control valves in the sample compartment provide simple and secure exchange of water thermostatted cells for temperature control with water baths. The  Peltier cell holder offers accurate temperature control with ±0.1° accuracy.

Validation and Regulatory Compliance

The automated validation program is compliant with GLP/cGMP and  FDA. The validation can be used for automated periodic testing of light source energy, zero repeatability, and rotational accuracy/repeatability. For guaranteed measurement accuracy, inspected filters and sample cells with certified optical path length can be used and NIST-traceable calibration standards are also available.

Ultimate Flexibility

With its single optical platform, the P-2000 can be customized to provide the optimum performance for every application. By selecting the most suitable combination of optical elements, the instrument can be used in the ultra-violet, visible and/or NIR regions.