Skip to content

JASCO JASCO

  • News
  • Events
  • E-Store
  • My Account
  • Contact Us
  • Worldwide
Search
Click to view menu
  • Products
    • Chromatography
      • HPLC
      • RHPLC
      • UHPLC
      • LC-MS
      • Preparative LC
      • Analytical SFC
      • Semi-Preparative SFC
      • Hybrid SFC
      • Fuel Analysis by SFC-FID
      • Preparative SFC
      • Supercritical Fluid Extraction
      • Chromatography Software
    • Molecular Spectroscopy
      • Circular Dichroism
      • High-Throughput CD
      • Vibrational CD
      • Circularly Polarized Luminescence (CPL)
      • Polarimeters
      • FTIR Spectrometers
      • FTIR Microscopy
      • FTIR Portable
      • Raman Microscopy
      • Palmtop Raman Spectrometer
      • Probe Raman
      • UV-Visible/NIR Spectrophotometers
      • UV-Visible/NIR Microscopy
      • Fluorescence Spectrophotometers
      • Film Thickness
      • Spectra Manager™ Suite
    • Refurbished
      • Refurbished HPLC Systems
      • HPLC Switching Valves
      • FTIR Accessories
  • Service
    • Service and Support Plans
    • Service Request Form
  • Applications
  • KnowledgeBase
  • Learning Center
    • Best Practice
      • Circular Dichroism Tips & Tricks for Biological Samples
      • CD Scale Calibration with ACS
      • Fluorescence Tips & Tricks
      • Raman Spectroscopy Tips & Tricks
    • Training Videos
      • ChromNAV
      • SF-NAV
      • Circular Dichroism
      • UV-Visible/NIR
      • Fluorescence
    • Training Seminars
      • Training Registration Form
    • Webinars
    • eBooks
    • Theory
      • Theory of Molecular Spectroscopy
      • Chromatography
  • About Us
    • President’s Message
    • Contact
    • History
    • Careers
  • News
  • Events
  • Worldwide
  • Shop
  • My Account
  • Contact Us

Home / Applications / Optical Rotation Measurement for Small Sample Amounts

  • Industry

  • Technique

Optical Rotation Measurement for Small Sample Amounts

By Heather Haffner

PDF IconDownload This Application

August 25, 2022

Introduction

P-2000 for Optical Rotation Measurement
P-2000 for Optical Rotation Measurement

Optical rotation measurement is a common analytical method used for the evaluation of synthesized compounds and compounds isolated and purified from natural products. In most of cases, the amount of material obtained during synthesis  and those obtained from natural product purification is usually very small. Therefore, it is essential to be able to measure these samples using the smallest amounts which requires the use of small volume cylindrical cells. This application note demonstrates the measurement of optical rotation using a  sample volume of only 1 mL.

Table 1. Cell sizes and recommended (minimum) sample volumes

 Cell DiameterCell path length: 100 mmCell path length: 50 mm
10 mm9 mL5 mL
3.5 mm1.6 mL1.4 mL
(1mL)
2.5 mm>1.4 mL
(1mL)
-
-
The values in ( ) are the minimum sample volume required for the measurement.

Polarimeter cell
Fig.1 Cylindrical Cell 2.5 mm D x 100 mm L

Features

  • P-2000 Polarimeter with sodium lamp and 589nm filter
  • PTC-262 Peltier cell holder for temperature controlled measurement
  • Minimum 1 mL sample volume (when using cells of 3.5 mm D x 50 mm L and 2.5 mm D  x 100 mm L)

Experimental

Sample preparation

10 mg of pirarubicin was accurately weighed and added to a 10 mL measuring flask, dissolved with chloroform and then diluted to 10 mL total volume (at 20°C).

Measurement conditions

Instrument:P-2000 Polarimeter
 PTC-262 Peltier thermostatted cell holder
Cells:Glass cells (size: 2.5 mm D x 100 mm L, 3.5 mm D x 100 mm L)
Light source/Wavelength:Sodium lamp / D589 line
Measurement Temperature:20°C

Note:

  • Temperature should be recorded prior to measurement as the probe may interfere with the light path.
  • Make sure that there are no bubbles in the cell, especially near the windows. Bubbles may cause inaccurate measurement.
  • If there is sufficient available sample available, it is recommended that a cell of 10 mm D x 100 L mm is used to obtain more simple and stable measurement results.

Keywords

pirarubicin, polarimeter, P-2000, optical rotation

Results

Measurement Results

 2.5 mm D x 100 mm L glass cell3.5mm L x 100 mm L glass cellDescription in JP
([α]D20: +195 ~ +215° (10 mg, 10 mL, 100 mm))
Optical rotation+0.2066°+0.2021°-
Specific optical rotation (α)+206.6°+202.1°+195 ~ +215°

Conclusion

Optical rotation measurement of pirarubicin

Among the pharmaceutical compounds  described in the various pharmacopoeias such as EP, USP and BP, there are requirements for optical rotation measurement of small sample volumes of valuable material. One such example is the measurement of optical rotation of pirarubicin ([α]D20: +195 ~ +215° (10 mg, chloroform, 10 mL, 100 mm)) indicated in the JP 16th Edition was measured with cells of 2.5 mm D x 100 mm L cell and 3.5 mm D x 100 mm L. The result shows that even the smallest amounts of sample can be easily measured.

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.

Featured Products:

  • Digital Polarimeters

  • P-2000

    Discrete sodium 589 nm D-line

    P-2000 Na+

  • P-2000

    Tungsten halogen lamp for applications in the visible region

    P-2000 WI

About the Author

JASCO Application Note

Optical Rotation Measurement for Small Sample Amounts

Introduction

P-2000 for Optical Rotation Measurement
P-2000 for Optical Rotation Measurement

Optical rotation measurement is a common analytical method used for the evaluation of synthesized compounds and compounds isolated and purified from natural products. In most of cases, the amount of material obtained during synthesis  and those obtained from natural product purification is usually very small. Therefore, it is essential to be able to measure these samples using the smallest amounts which requires the use of small volume cylindrical cells. This application note demonstrates the measurement of optical rotation using a  sample volume of only 1 mL.

Table 1. Cell sizes and recommended (minimum) sample volumes

 Cell DiameterCell path length: 100 mmCell path length: 50 mm
10 mm9 mL5 mL
3.5 mm1.6 mL1.4 mL
(1mL)
2.5 mm>1.4 mL
(1mL)
-
-
The values in ( ) are the minimum sample volume required for the measurement.

Polarimeter cell
Fig.1 Cylindrical Cell 2.5 mm D x 100 mm L

Features

  • P-2000 Polarimeter with sodium lamp and 589nm filter
  • PTC-262 Peltier cell holder for temperature controlled measurement
  • Minimum 1 mL sample volume (when using cells of 3.5 mm D x 50 mm L and 2.5 mm D  x 100 mm L)

Experimental

Sample preparation

10 mg of pirarubicin was accurately weighed and added to a 10 mL measuring flask, dissolved with chloroform and then diluted to 10 mL total volume (at 20°C).

Measurement conditions

Instrument:P-2000 Polarimeter
 PTC-262 Peltier thermostatted cell holder
Cells:Glass cells (size: 2.5 mm D x 100 mm L, 3.5 mm D x 100 mm L)
Light source/Wavelength:Sodium lamp / D589 line
Measurement Temperature:20°C

Note:

  • Temperature should be recorded prior to measurement as the probe may interfere with the light path.
  • Make sure that there are no bubbles in the cell, especially near the windows. Bubbles may cause inaccurate measurement.
  • If there is sufficient available sample available, it is recommended that a cell of 10 mm D x 100 L mm is used to obtain more simple and stable measurement results.

Results

Measurement Results

 2.5 mm D x 100 mm L glass cell3.5mm L x 100 mm L glass cellDescription in JP
([α]D20: +195 ~ +215° (10 mg, 10 mL, 100 mm))
Optical rotation+0.2066°+0.2021°-
Specific optical rotation (α)+206.6°+202.1°+195 ~ +215°

Conclusion

Optical rotation measurement of pirarubicin

Among the pharmaceutical compounds  described in the various pharmacopoeias such as EP, USP and BP, there are requirements for optical rotation measurement of small sample volumes of valuable material. One such example is the measurement of optical rotation of pirarubicin ([α]D20: +195 ~ +215° (10 mg, chloroform, 10 mL, 100 mm)) indicated in the JP 16th Edition was measured with cells of 2.5 mm D x 100 mm L cell and 3.5 mm D x 100 mm L. The result shows that even the smallest amounts of sample can be easily measured.

Keywords

pirarubicin, polarimeter, P-2000, optical rotation

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.
28600 Mary’s Court, Easton, MD 21601 USA • (800) 333-5272 • Fax: (410) 822-7526 • jascoinc.com/applications

Close

Designed in Tokyo. TRUSTED globally.

View our support plans

Connect with JASCO

  • Facebook
  • Twitter
  • LinkedIn
  • JASCO Sales
  • 800-333-5272

Receive the latest promotions and special offers

  • This field is for validation purposes and should be left unchanged.
  • Careers
  • Press Kit
  • JASCO Privacy Policy
  • Sitemap
  • Environmental Policy

© , JASCO. All Rights Reserved.