Skip to content

JASCO JASCO

  • News
  • Events
  • E-Store
  • My Account
  • Contact Us
  • Worldwide
Search
Click to view menu
  • Products
    • Chromatography
      • HPLC
      • RHPLC
      • UHPLC
      • LC-MS
      • Preparative LC
      • Analytical SFC
      • Semi-Preparative SFC
      • Hybrid SFC
      • Fuel Analysis by SFC-FID
      • Preparative SFC
      • Supercritical Fluid Extraction
      • Chromatography Software
    • Molecular Spectroscopy
      • Circular Dichroism
      • High-Throughput CD
      • Vibrational CD
      • Circularly Polarized Luminescence (CPL)
      • Polarimeters
      • FTIR Spectrometers
      • FTIR Microscopy
      • FTIR Portable
      • Raman Microscopy
      • Palmtop Raman Spectrometer
      • Probe Raman
      • UV-Visible/NIR Spectrophotometers
      • UV-Visible/NIR Microscopy
      • Fluorescence Spectrophotometers
      • Film Thickness
      • Spectra Manager™ Suite
    • Refurbished
      • Refurbished HPLC Systems
      • HPLC Switching Valves
      • FTIR Accessories
  • Service
    • Service and Support Plans
    • Service Request Form
  • Applications
  • KnowledgeBase
  • Learning Center
    • Best Practice
      • Circular Dichroism Tips & Tricks for Biological Samples
      • CD Scale Calibration with ACS
      • Fluorescence Tips & Tricks
      • Raman Spectroscopy Tips & Tricks
    • Training Videos
      • ChromNAV
      • SF-NAV
      • Circular Dichroism
      • UV-Visible/NIR
      • Fluorescence
    • Training Seminars
      • Training Registration Form
    • Webinars
    • eBooks
    • Theory
      • Theory of Molecular Spectroscopy
      • Chromatography
  • About Us
    • President’s Message
    • Contact
    • History
    • Careers
  • News
  • Events
  • Worldwide
  • Shop
  • My Account
  • Contact Us

Home / Applications / IR Microscope with Heating/Cooling Stage for the Evaluation of the Melting Point or Phase Transition of a Sample at the Molecular Level

  • Industry

  • Technique

IR Microscope with Heating/Cooling Stage for the Evaluation of the Melting Point or Phase Transition of a Sample at the Molecular Level

By Carlos Morillo

PDF IconDownload This Application

March 25, 2024

Introduction

IRT-5000 and Heating Stage
Fig. 1 IRT-5000 and Heating Stage

Differential Scanning Calorimetry (DSC) or Thermo Gravimetric Analysis (TGA) are generally used to evaluate thermophysical properties such as melting points or phase transitions. These techniques are used in combination with X-Ray Diffraction (XRD) to assess thermophysical properties and crystal structure.

The JASCO IRT-5000 and IRT-7000 IR microscopes can be combined with a sample heating system, MHC-5000 (Fig. 1, Chart 1), which allows changes in molecules to be measured for their thermophysical properties with image observation. The heating system uniformly heats or cools the measurement area in the IR microscope, assuring high accuracy measurement. Temperature and measurement conditions are software controlled with simultaneous image scanning and IR measurement.

Chart 1 Temperature Control Range of Heating Stage
ModelMHC-5000(Option)
Temperature RangeRoom Temperature ~ 600° C-190 ~ 600° C

Experimental

3D spectrum of benzoic acid
Figure 2. 3D spectrum of benzoic acid

The IRT-5000 IR microscope with MHC-5000 was used to measure benzoic acid heated from 100° C up to 150° C with a ramping rate of 2° C per minute and IR spectra were obtained at 0.5˚ C intervals.


Change of peak intensity at 930 cm-1
Figure 3. Change of peak intensity at 930 cm-1

Fig. 2 3-Dimensional spectra of benzoic acid with changes in temperature, Fig. 3 change in peak intensity at 930 cm-1 versus temperature and Fig. 4 optical images of benzoic acid with the change in temperature from 120 to 125˚ C. Structural changes in the benzoic acid were confirmed between 120° C and 125° C. Since the melting point of the benzoic acid is 122.4° C*, the molecular structure change due to melting was clearly observed with this system. It can be concluded that this system is useful for measurement of thermal structural changes, such as denaturation of proteins or hardening of thermoset resins.

Observation image of benzoic acid in each temperature
Figure 4. Observation image of benzoic acid in each temperature

*Ref. Encyclopedia of Chemistry

 

Keywords

280-TC-0001, IR Microscope, IRT-5000, IRT-7000, phase transition, melting point, benzoic acid, thermoset resin

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.

Featured Products

  • The IRT-5000 is an innovative FTIR microscope with powerful sample identification and imaging.

    IRT-5000 Series FTIR Microscopes

  • The IRT-7000 16-element linear array microscope for fast imaging and kinetics.

    IRT-7000 FTIR Microscope

About the Author

Dr. Carlos Morillo received his Post Doc at Advanced Industrial Science & Technology in Fukuoka and was a Research Scientist at Kyushu University in Japan where he lived for several years. Carlos received his Doctor of Engineering from Kyushu University and his Masters and BS from Simon Bolivar University in Caracas Venezuela. He is an Applications Scientist at JASCO.

JASCO Application Note

IR Microscope with Heating/Cooling Stage for the Evaluation of the Melting Point or Phase Transition of a Sample at the Molecular Level

Introduction

IRT-5000 and Heating Stage
Fig. 1 IRT-5000 and Heating Stage

Differential Scanning Calorimetry (DSC) or Thermo Gravimetric Analysis (TGA) are generally used to evaluate thermophysical properties such as melting points or phase transitions. These techniques are used in combination with X-Ray Diffraction (XRD) to assess thermophysical properties and crystal structure.

The JASCO IRT-5000 and IRT-7000 IR microscopes can be combined with a sample heating system, MHC-5000 (Fig. 1, Chart 1), which allows changes in molecules to be measured for their thermophysical properties with image observation. The heating system uniformly heats or cools the measurement area in the IR microscope, assuring high accuracy measurement. Temperature and measurement conditions are software controlled with simultaneous image scanning and IR measurement.

Chart 1 Temperature Control Range of Heating Stage
ModelMHC-5000(Option)
Temperature RangeRoom Temperature ~ 600° C-190 ~ 600° C

Experimental

3D spectrum of benzoic acid
Figure 2. 3D spectrum of benzoic acid

The IRT-5000 IR microscope with MHC-5000 was used to measure benzoic acid heated from 100° C up to 150° C with a ramping rate of 2° C per minute and IR spectra were obtained at 0.5˚ C intervals.


Change of peak intensity at 930 cm-1
Figure 3. Change of peak intensity at 930 cm-1

Fig. 2 3-Dimensional spectra of benzoic acid with changes in temperature, Fig. 3 change in peak intensity at 930 cm-1 versus temperature and Fig. 4 optical images of benzoic acid with the change in temperature from 120 to 125˚ C. Structural changes in the benzoic acid were confirmed between 120° C and 125° C. Since the melting point of the benzoic acid is 122.4° C*, the molecular structure change due to melting was clearly observed with this system. It can be concluded that this system is useful for measurement of thermal structural changes, such as denaturation of proteins or hardening of thermoset resins.

Observation image of benzoic acid in each temperature
Figure 4. Observation image of benzoic acid in each temperature

*Ref. Encyclopedia of Chemistry

 

Keywords

280-TC-0001, IR Microscope, IRT-5000, IRT-7000, phase transition, melting point, benzoic acid, thermoset resin

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.
28600 Mary’s Court, Easton, MD 21601 USA • (800) 333-5272 • Fax: (410) 822-7526 • jascoinc.com/applications

Close

Designed in Tokyo. TRUSTED globally.

View our support plans

Connect with JASCO

  • Facebook
  • Twitter
  • LinkedIn
  • JASCO Sales
  • 800-333-5272

Receive the latest promotions and special offers

  • This field is for validation purposes and should be left unchanged.
  • Careers
  • Press Kit
  • JASCO Privacy Policy
  • Sitemap
  • Environmental Policy

© , JASCO. All Rights Reserved.