Skip to content

JASCO JASCO

  • News
  • Events
  • E-Store
  • My Account
  • Contact Us
  • Worldwide
Search
Click to view menu
MENUMENU
  • Products
    • Chromatography
      • HPLC
      • RHPLC
      • UHPLC
      • LC-MS
      • Preparative LC
      • Analytical SFC
      • Semi-Preparative SFC
      • Hybrid SFC
      • Fuel Analysis by SFC-FID
      • Preparative SFC
      • Supercritical Fluid Extraction
      • Chromatography Software
    • Molecular Spectroscopy
      • Circular Dichroism
      • High-Throughput CD
      • Vibrational CD
      • Circularly Polarized Luminescence (CPL)
      • Polarimeters
      • FTIR Spectrometers
      • FTIR Microscopy
      • FTIR Portable
      • Raman Microscopy
      • Palmtop Raman Spectrometer
      • Probe Raman
      • UV-Visible/NIR Spectrophotometers
      • UV-Visible/NIR Microscopy
      • Fluorescence Spectrophotometers
      • Film Thickness
      • Spectra Manager™ Suite
    • Refurbished
      • Refurbished HPLC Systems
      • HPLC Switching Valves
      • FTIR Accessories
  • Service
    • Service and Support Plans
    • Service Request Form
  • Applications
  • KnowledgeBase
  • Learning Center
    • Best Practice
      • Circular Dichroism Tips & Tricks for Biological Samples
      • CD Scale Calibration with ACS
      • Fluorescence Tips & Tricks
      • Raman Spectroscopy Tips & Tricks
    • Training Videos
      • ChromNAV
      • SF-NAV
      • Circular Dichroism
      • UV-Visible/NIR
      • Fluorescence
    • Training Seminars
      • Training Registration Form
    • Webinars
    • eBooks
    • Theory
      • Theory of Molecular Spectroscopy
      • Chromatography
  • About Us
    • President’s Message
    • Contact
    • History
    • Careers
  • News
  • Events
  • Worldwide
  • Shop
  • My Account
  • Contact Us

Home / Applications / Rapid Separation of Steroid Drugs (Betamethasone) using UHPLC

  • Industry

  • Technique

Rapid Separation of Steroid Drugs (Betamethasone) using UHPLC

By Satoe Iijima

PDF IconDownload This Application

January 5, 2024

Introduction

Betamethasone, a steroid, is administered to reduce tissue inflammation or to suppress the human immune system. The U.S. Pharmacopeia (1) (USP) method requires that HPLC analysis of components of a betamethasone drug should have a resolution, R, between the analyte and internal standard peaks to be not less than 1.7 and the relative standard deviation for replicate injections to be no greater than 2.0%.

Cortisone acetate is also a steroid that has a similar biological effect to betamethasone, and is administered to patients who have the same symptoms. Similarly, the Japanese Pharmacopoeia (2) JP method requires that HPLC analysis of components of a cortisone drug should have a resolution, R, between the analyte and internal standard (propyl paraben) peaks greater than 4; and the relative standard deviation for replicate injections to be no more than 1.0%.

We examined the utility of an X-PressPak C18S column (2.1 mm i.d. x 50 mm L.) with 2µm particle size for the high speed separation of the above steroid drugs. The results were evaluated to determine whether the performance of the column and chromatography separation meets the USP and JP requirements.

Experimental

X-LC system for separation of steroid drugs components

The system used in these experiments was a X-LC system comprising of a 3085PU HPLC pump, 3080DG degasser, 3067CO column oven, 3070UV UV-visible detector, and 3059AS auto sampler.

Keywords

747009X

Results

Figure 1 Outlines the separation of a standard mixture of betamethazone (0.04 mg/mL) and butyl paraben (0.057 mg/mL). The X-LC system provides an analysis time 9 times shorter than conventional HPLC with a resolution between the betamethazone and butyl paraben peaks of 18.8; the reproducibility of the peak ratio is 0.44%. These results are well within the USP requirements for the analysis.

Figure 2 Separation of a standard mixture of propyl paraben (0.03 mg/mL), butyl paraben (0.03 mg/mL), and cortisone acetate (0.1 mg/mL). In this example, the UHPLC separation provides an analysis time 4 times shorter than conventional HPLC with a resolution between the propyl paraben and cortisone acetate elutions of 12.2; the reproducibility for the peak ratio as small as 0.44%. These results are also within the JP requirements for the analysis.

Figure 1. UHPLC chromatogram of a standard mixture of betamethazone, and butyl paraben

Peaks: 1 = betamethazone (0.04 mg/mL), and 2 = butyl paraben (0.057 mg/mL).

Conditions: column = X-PressPak C18 (2.1 mm I.D. x 50 mm L); column temperature = 25 C; mobile phase = acetonitrile/water (40/60); flow rate = 0.7 mL/min; detection wavelength = 240 nm; injection volume = 1 mL.

Figure 2. UHPLC chromatogram of a standard mixture of propylparaben, butyl paraben, and cortisone acetate

Peaks: 1 = propylparaben (0.03 mg/mL),2 = butyl paraben (0.03 mg/mL), and 3 = cortisone acetate (0.1 mg/mL).

Conditions: column = XPressPak C18 (2.1 mm I.D. x 50 mm L); column temperature = 25’C; mobile phase = acetonitrile/water (35/65); flow rate = 0.7 mL/min; detection wavelength = 254 nm; injection volume = 1 mL.

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.

Featured Products:

  • LC-4000 Series UHPLC

  • Column Ovens

  • LC-4000 Series RHPLC

About the Author

Ms Iijima is a member of the chromatography separations team at JASCO Corporation main applications laboratory in Tokyo Japan.

JASCO Application Note

Rapid Separation of Steroid Drugs (Betamethasone) using UHPLC

Introduction

Betamethasone, a steroid, is administered to reduce tissue inflammation or to suppress the human immune system. The U.S. Pharmacopeia (1) (USP) method requires that HPLC analysis of components of a betamethasone drug should have a resolution, R, between the analyte and internal standard peaks to be not less than 1.7 and the relative standard deviation for replicate injections to be no greater than 2.0%.

Cortisone acetate is also a steroid that has a similar biological effect to betamethasone, and is administered to patients who have the same symptoms. Similarly, the Japanese Pharmacopoeia (2) JP method requires that HPLC analysis of components of a cortisone drug should have a resolution, R, between the analyte and internal standard (propyl paraben) peaks greater than 4; and the relative standard deviation for replicate injections to be no more than 1.0%.

We examined the utility of an X-PressPak C18S column (2.1 mm i.d. x 50 mm L.) with 2µm particle size for the high speed separation of the above steroid drugs. The results were evaluated to determine whether the performance of the column and chromatography separation meets the USP and JP requirements.

Experimental

X-LC system for separation of steroid drugs components

The system used in these experiments was a X-LC system comprising of a 3085PU HPLC pump, 3080DG degasser, 3067CO column oven, 3070UV UV-visible detector, and 3059AS auto sampler.

Results

Figure 1 Outlines the separation of a standard mixture of betamethazone (0.04 mg/mL) and butyl paraben (0.057 mg/mL). The X-LC system provides an analysis time 9 times shorter than conventional HPLC with a resolution between the betamethazone and butyl paraben peaks of 18.8; the reproducibility of the peak ratio is 0.44%. These results are well within the USP requirements for the analysis.

Figure 2 Separation of a standard mixture of propyl paraben (0.03 mg/mL), butyl paraben (0.03 mg/mL), and cortisone acetate (0.1 mg/mL). In this example, the UHPLC separation provides an analysis time 4 times shorter than conventional HPLC with a resolution between the propyl paraben and cortisone acetate elutions of 12.2; the reproducibility for the peak ratio as small as 0.44%. These results are also within the JP requirements for the analysis.

Figure 1. UHPLC chromatogram of a standard mixture of betamethazone, and butyl paraben

Peaks: 1 = betamethazone (0.04 mg/mL), and 2 = butyl paraben (0.057 mg/mL).

Conditions: column = X-PressPak C18 (2.1 mm I.D. x 50 mm L); column temperature = 25 C; mobile phase = acetonitrile/water (40/60); flow rate = 0.7 mL/min; detection wavelength = 240 nm; injection volume = 1 mL.

Figure 2. UHPLC chromatogram of a standard mixture of propylparaben, butyl paraben, and cortisone acetate

Peaks: 1 = propylparaben (0.03 mg/mL),2 = butyl paraben (0.03 mg/mL), and 3 = cortisone acetate (0.1 mg/mL).

Conditions: column = XPressPak C18 (2.1 mm I.D. x 50 mm L); column temperature = 25’C; mobile phase = acetonitrile/water (35/65); flow rate = 0.7 mL/min; detection wavelength = 254 nm; injection volume = 1 mL.

Keywords

747009X

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.
28600 Mary’s Court, Easton, MD 21601 USA • (800) 333-5272 • Fax: (410) 822-7526 • jascoinc.com/applications

Close

Designed in Tokyo. TRUSTED globally.

View our support plans

Connect with JASCO

  • Facebook
  • Twitter
  • LinkedIn
  • JASCO Sales
  • 800-333-5272

Receive the latest promotions and special offers

  • This field is for validation purposes and should be left unchanged.
  • Careers
  • Press Kit
  • JASCO Privacy Policy
  • Sitemap
  • Environmental Policy

© , JASCO. All Rights Reserved.