Fluorescence Spectrometers Specifications

Spectrometer Specification

Model
FP-8250
FP-8350
FP-8550
FP-8650
Light Source
Continuous output Xe arc lamp with shielded lamp housing (150 W) Lifetime 3000 hours
Light Source (for validation)
Integrated, selectable low pressure mercury lamp
Photometric System
Ratio-photometer system using monochromatic light to monitor the intensity output of the Xe lamp
Monochromator
Holographic concave grating in modified Rowland mount
Wavelength Range (with Standard Detector)
Ex
Zero order, 200 - 750 nm
Zero order, 200 - 750 nm
Zero order, 200 - 850 nm
Zero order, 200 - 850 nm
Em
Zero order, 200 - 980nm
Wavelength Range (Optional)
200 - 900nm
200 - 1010nm
Automatic Cut Filters for High Order Diffraction
Option
Standard
Sensitivity *1 (RMS)
Base *2
4,500 : 1
8,000 : 1
8,500 : 1
3,500 : 1
Band Width
Ex
2.5, 5, 10, 20 nm
1, 2.5, 5, 10, 20 nm
1, 2.5, 5, 10, 20, L5, L10 nm
1, 2.5, 5, 10, 20, L5, L10 nm
Em
2.5, 10, 20, 40, L10, L20 nm
Wavelength Accuracy
Ex
±2.0 nm
±1.5 nm
±1.0 nm
±1.0 nm
Em
±2.0 nm
Wavelength Scan Speed
Ex
20, 50, 100, 200, 500, 1,000, 2,000, 5,000,
10,000, 20,000 nm/min
10, 20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000,
60,000 nm/min
10, 20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000, 60,000 nm/min
Em
20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000, 60,000, 120,000 nm/min
Detector
Ex: Silicon photodiode, Em: PMT
Auto Gain
Standard
Shutter Function
Standard (Automatic control)
Sample Illuminating System
Horizontal illumination
Sample Compartment
10 mm rectangular cell holder, nitrogen purgeable
Accessory Recognition
Standard
Start Button
Standard
Analog Output
Standard
Instrument Communication
USB 2.0
Control and Data Processing
Spectra Manager™/CFR, iRM
Spectra Manager™/CFR
Spectral Correction
Option
Standard
(Spectral correction using a Rhodamine B ethylene glycol solution is standard; other jigs for spectral correction are available separately as options.)
Dimensions
520(W) × 545(D) × 270(H) mm
570(W) × 545(D) × 270(H) mm
Weight
36 kg (79 lbs)
39 kg (86 lbs)
Power Requirement
270VA
Installation Environment
Temperature: 15 to 35°C, Humidity: Less than 85%

*1 : Minimum Signal-to-Noise ratio of Raman band of water, excitation 350 nm, band width Ex 5 nm Em 5 nm (FP-8650: Ex 5 nm Em 10 nm), response 2 seconds.
*2 : Noise is measured on the baseline.

Software Specification

A wide range of software applications and accessories can be used with Spectra Manager™ Suite.

Model
FP-8250
FP-8350
FP-8550
FP-8650
Data Station Type
Spectra Manager™/Spectra Manager™ CFR (Microsoft Windows® 10 Professional or Enterprise)
iRM Type
Handheld Intelligent Remote Module iRM-900
Not Used
Measurement Programs
Spectra Manager™
Spectra measurement,

Quantitative measurement,

Fixed wavelength measurement,

Time course measurement,

3D Spectra measurement,

Absorbance measurement
Spectra measurement,

Quantitative measurement,

Fixed wavelength measurement,

Time course measurement,

3D Spectra measurement,

Absorbance measurement,

Phosphorescence measurement
Spectra Manager™ CFR *4
iRM-900 *5
Spectra measurement, Quantitative measurement, Fixed wavelength measurement, Time course measurement, 3D Spectra measurement, Absorbance measurement
Not Used
Spectra Correction Program
Standard *6
Standard
Daily Check
Standard
Instrument Validation
Program and Hg lamp (Standard), Accessories (option)
Program and Hg lamp (Standard), Accessories (Standard)
Self Diagnosis
Standard
IQ Accessory Recognition and IQ Start
Standard

*4 : Spectra Manager™ CFR is the 21 CFR Part 11 compliant software package.
*5 : The iRM-900 handheld control module can be used with any PictBridge compatible printer.
*6 : Optional components are necessary.
Specifications are subject to change without notice.