ASU-800 Autosampler Unit

Automates the measurement of multiple liquid samples when used with a sipper or syringe pump. Various optional racks can be used with a range of test tubes, vials or microplates.

ASU-800 Autosampler Unit

Compatible PumpType
NQF-781Vacuum Sipper
NQF-783Vacuum Sipper with Long-path flow cell
NPF-782Peristaltic Sipper
ASP-849Syringe Pump
NameRackSamplesMax No. of Samples
SRA-81115 mm O.D. Test tube10 mL100
SRA-81213 mm O.D. Test tube7 mL100
SRA-81312 mm O.D. Test tube5 mL150
SRA-81410 mm O.D. Test tube3 mL150
SRA-816Micro Plate Rack1 mL196
SRA-818Vial Rack1.5 mL120
ASU-800 with NPF-782 Peristaltic Sipper
ASU-800 with NPF-782 Peristaltic Sipper
ASU-800 with NQF-781 Vacuum Sipper
ASU-800 with ASP-849 Syringe Pump and SFC-712 Micro Flow Cell

 

ASU-800 with ASP-849 Syringe Pump and SFC-712 Micro Flow Cell
ASU-800 with NQF-781 with Vacuum Sipper

 

ASP-849 Syringe Pump

Used with the ASU-800 and SFC-712 flow cell holder. The syringe pump is suitable for measurement of small sample volumes. The unit includes a 2.5 mL syringe (1, 5, and 10 mL are optional).

Reproducibitliy of Volume DeliveryWithin %1
Syringe Capacity2.5 mL (1, 5, 10 mL options)

NQF-930 Vacuum Sipper

Vacuum sipper for fast measurement, the sample cannot be recovered. Path length 10 mm.

NQF-930 Vacuum Sipper

NQF-929 Vacuum Sipper with Long-Path Flow Cell

Vacuum sipper for fast measurement, the sample cannot be recovered. Path length 50 mm.

NPF-782 Peristaltic Sipper

Peristaltic sipper with sample recovery. Path length 10mm, can also be used with standard 10×10 mm cuvette by switching-out the flow cell

NPF-782 Peristaltic Sipper

Sippers
Flow Cells
NPF-782
NQF-929
NQF-930
SFC-712
LFC-713
Light Path Length10 mm10 mm50 mm10 mm5 mm30 mm50 mm100 mm
Cell CapacityApprox. 70 uLApprox. 70 uLApprox. 1400 uLApprox. 100 μLApprox. 50 μLApprox. 600 μLApprox. 1000 μLApprox. 2000 μL
Cell MaterialQuartzQuartzQuartzQuartzQuartzQuartzQuartzQuartz
CarryoverLess than 1%Less than 1%Less than 1%
Minimum Sample Requirement0.7 mL with low-viscosity samples0.7 mL with low-viscosity samples1.4 mL with low-viscosity samples
Wavelength RangeV-730220-900 nm 220-900 nm 220-900 nm 220-1100 nm220-1100 nm220-1100 nm220-1100 nm220-1100 nm
V-750/760220-900 nm220-900 nm220-900 nm220-900 nm220-900 nm220-900 nm220-900 nm220-900 nm
V-770220-2200 nm220-2200 nm220-2200 nm220-2700 nm220-2700 nm220-2700 nm220-2700 nm220-2700 nm
V-780220-1600 nm220-1600 nm220-1600 nm220-1600 nm220-1600 nm220-1600 nm220-1600 nm220-1600 nm