Skip to content

JASCO JASCO

  • News
  • Events
  • E-Store
  • My Account
  • Contact Us
  • Worldwide
Search
Click to view menu
  • Products
    • Chromatography
      • HPLC
      • RHPLC
      • UHPLC
      • LC-MS
      • Preparative LC
      • Analytical SFC
      • Semi-Preparative SFC
      • Hybrid SFC
      • Fuel Analysis by SFC-FID
      • Preparative SFC
      • Supercritical Fluid Extraction
      • Chromatography Software
    • Molecular Spectroscopy
      • Circular Dichroism
      • High-Throughput CD
      • Vibrational CD
      • Circularly Polarized Luminescence (CPL)
      • Polarimeters
      • FTIR Spectrometers
      • FTIR Microscopy
      • FTIR Portable
      • Raman Microscopy
      • Palmtop Raman Spectrometer
      • Probe Raman
      • UV-Visible/NIR Spectrophotometers
      • UV-Visible/NIR Microscopy
      • Fluorescence Spectrophotometers
      • Film Thickness
      • Spectra Manager™ Suite
    • Refurbished
      • Refurbished HPLC Systems
      • HPLC Switching Valves
      • FTIR Accessories
  • Service
    • Service and Support Plans
    • Service Request Form
  • Applications
  • KnowledgeBase
  • Learning Center
    • Best Practice
      • Circular Dichroism Tips & Tricks for Biological Samples
      • CD Scale Calibration with ACS
      • Fluorescence Tips & Tricks
      • Raman Spectroscopy Tips & Tricks
    • Training Videos
      • ChromNAV
      • SF-NAV
      • Circular Dichroism
      • UV-Visible/NIR
      • Fluorescence
    • Training Seminars
      • Training Registration Form
    • Webinars
    • eBooks
    • Theory
      • Theory of Molecular Spectroscopy
      • Chromatography
  • About Us
    • President’s Message
    • Contact
    • History
    • Careers
  • News
  • Events
  • Worldwide
  • Shop
  • My Account
  • Contact Us

Home / Applications / IRT-5000 FTIR Microscope with IQ Mapping

  • Industry

  • Technique

IRT-5000 FTIR Microscope with IQ Mapping

By Miyuki Kanno

PDF IconDownload This Application

May 2, 2024

Introduction

An FTIR microscope can be used for mapping measurement, which provides an ‘image’ of the distribution of chemical structure at the surface of a material. This can be useful for many different applications.

FTIR Microscope
Fig. 1 FT/IR-4600 + IRT-5200

Using a linear array detector can shorten the measurement time by more than an order of magnitude in comparison with conventional systems and makes FTIR microscopy a more favorable technique.

The powerful IQ Mapping system was developed for two reasons, the first to allow mapping of samples that can be easily damaged or is moved by the frequent lift and replace measurement required to map an image using an ATR.  This is useful for soft materials, textile threads or suspended particles. The second is to eliminate the requirement of a more expensive autostage. IQ Mapping can be used with ATR, transmittance or reflectance to map an area using a manual stage by precisely a controlled rastering mirror which directs the IR beam through the cassegrain across the sample surface. Below is an example of impurity analysis using IQ Mapping using an IRT-5200 FTIR microscope (Fig. 1).

By analyzing the spectra in Fig. 3, it was confirmed that the multi-layer film consists of three components, PVA (red), PVC (blue), and protein (green). Using a color distribution map to identify key peaks for each component on the RGB display (Fig. 4), the component distribution is readily visualized, this enables quick and easy detection of impurities that cannot be identified by a simple visual inspection of the sample.

Measurement 2: ATR Mapping

Combining IQ Mapping with ATR enables mapping without cross contamination caused by repeatedly touching the ATR to the sample. IQ mapping requires only a single touch point and is able to create a map by precisely directing light through an array of positions (up to 400 x 400 μm with a wide angle ATR) on the crystal. The sample shown in Fig. 5 was measured using a ZnSe ATR prism.

Measurement conditions: Detector: MCT-N, Resolution: 8 cm-1, Accumulation: 8, Cassegrain: ATR-Z-5000, Aperture: 20×20 μm, Measurement points: 6 x 6, Sampling area: 100 x 100 μm

Analysis of the spectra in the mapped area reveals two different components that appeared by visual inspection to be uniform, as shown in the visible image in Fig. 5. The sample was a mixture of water-based and oil-based marker, and specific peaks for each could be identified as shown in Fig. 6. The color distribution map used uniquely identifying peaks for each component (1666 cm-1 and 1282 cm-1) to delineate the areas where each component was present, this is shown in Fig. 7. With the appropriate software tools and the ease of use of IQ mapping, users can rapidly detect non-homogeneity in samples which may appear to be a single component by visual inspection, providing confidence needed for highly accurate qualitative analysis.

Keywords

100-SO-0238

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.

Featured Products:

  • The IRT-5000 is an innovative FTIR microscope with powerful sample identification and imaging.

    IRT-5000 Series FTIR Microscopes

  • The IRT-7000 16-element linear array microscope for fast imaging and kinetics.

    IRT-7000 FTIR Microscope

About the Author

Miyuki Kanno

JASCO Application Note

IRT-5000 FTIR Microscope with IQ Mapping

Introduction

An FTIR microscope can be used for mapping measurement, which provides an ‘image’ of the distribution of chemical structure at the surface of a material. This can be useful for many different applications.

FTIR Microscope
Fig. 1 FT/IR-4600 + IRT-5200

Using a linear array detector can shorten the measurement time by more than an order of magnitude in comparison with conventional systems and makes FTIR microscopy a more favorable technique.

The powerful IQ Mapping system was developed for two reasons, the first to allow mapping of samples that can be easily damaged or is moved by the frequent lift and replace measurement required to map an image using an ATR.  This is useful for soft materials, textile threads or suspended particles. The second is to eliminate the requirement of a more expensive autostage. IQ Mapping can be used with ATR, transmittance or reflectance to map an area using a manual stage by precisely a controlled rastering mirror which directs the IR beam through the cassegrain across the sample surface. Below is an example of impurity analysis using IQ Mapping using an IRT-5200 FTIR microscope (Fig. 1).

By analyzing the spectra in Fig. 3, it was confirmed that the multi-layer film consists of three components, PVA (red), PVC (blue), and protein (green). Using a color distribution map to identify key peaks for each component on the RGB display (Fig. 4), the component distribution is readily visualized, this enables quick and easy detection of impurities that cannot be identified by a simple visual inspection of the sample.

Measurement 2: ATR Mapping

Combining IQ Mapping with ATR enables mapping without cross contamination caused by repeatedly touching the ATR to the sample. IQ mapping requires only a single touch point and is able to create a map by precisely directing light through an array of positions (up to 400 x 400 μm with a wide angle ATR) on the crystal. The sample shown in Fig. 5 was measured using a ZnSe ATR prism.

Measurement conditions: Detector: MCT-N, Resolution: 8 cm-1, Accumulation: 8, Cassegrain: ATR-Z-5000, Aperture: 20×20 μm, Measurement points: 6 x 6, Sampling area: 100 x 100 μm

Analysis of the spectra in the mapped area reveals two different components that appeared by visual inspection to be uniform, as shown in the visible image in Fig. 5. The sample was a mixture of water-based and oil-based marker, and specific peaks for each could be identified as shown in Fig. 6. The color distribution map used uniquely identifying peaks for each component (1666 cm-1 and 1282 cm-1) to delineate the areas where each component was present, this is shown in Fig. 7. With the appropriate software tools and the ease of use of IQ mapping, users can rapidly detect non-homogeneity in samples which may appear to be a single component by visual inspection, providing confidence needed for highly accurate qualitative analysis.

Keywords

100-SO-0238

This document has been prepared based on information available at the time of publication and is subject to revision without notice. Although the contents are checked with the utmost care, we do not guarantee their accuracy or completeness. JASCO Corporation assumes no responsibility or liability for any loss or damage incurred as a result of the use of any information contained in this document. Copyright and other intellectual property rights in this document remain the property of JASCO Corporation. Please do not attempt to copy, modify, redistribute, or sell etc. in whole or in part without prior written permission.
28600 Mary’s Court, Easton, MD 21601 USA • (800) 333-5272 • Fax: (410) 822-7526 • jascoinc.com/applications

Close

Designed in Tokyo. TRUSTED globally.

View our support plans

Connect with JASCO

  • Facebook
  • Twitter
  • LinkedIn
  • JASCO Sales
  • 800-333-5272

Receive the latest promotions and special offers

  • This field is for validation purposes and should be left unchanged.
  • Careers
  • Press Kit
  • JASCO Privacy Policy
  • Sitemap
  • Environmental Policy

© , JASCO. All Rights Reserved.