IRT-7000 FTIR Linear Array Imaging Microscope

With fast 16 element MCT detector and IQ Mapping - for the fastest sample imaging.

FTIR Linear Array Imaging Microscope
IRT-7000 FTIR Linear Array Imaging Microscope

FTIR Linear Array Imaging Microscope

The IRT-7000  is a very fast FTIR Linear Array Imaging Microscope that can be interfaced with a FT/IR-6X or 8X Series FTIR spectrometer, offering the most advanced microscopy and imaging system. The 16-element MCT offers a faster response with excellent signal-to-noise and a wider wavelength range than a focal plane array detector. The data processing is done using onboard computing so that there is no delay in data being delivered to the imaging software. Mapping and imaging are done in real-time, so that you can see the chemical distribution as the sample is measured,

System Description

The IRT-7000 includes up to two detectors as standard; a 16-channel linear array detector for fast sample imaging and a single-point MCT detector (with a wider spectral range and enhanced sensitivity. The combination of the automatic sample stage and IQ Mapping offers high-speed mapping analyses over a very large sample area, multi-area ATR mapping, and IR imaging with a spatial resolution close to the diffraction limit with excellent sensitivity in a short time. In combination with the FT/IR-6X/8X with Rapid Scan or Step Scan options, this system offers advanced dynamic imaging as well as time-resolved measurements. For multivariate analysis, Principal Component Analysis (PCA) is included as standard.

System Features

  • IQ Mapping for in-situ mapping experiments for high speed or samples that can be easily damaged when the ATR is moved
  • Rapid IR Imaging experiments
  • Automatic revolver with up to four objectives with automatic switching
  • Exceptional visual observation quality with DIC and polarization options
  • Wide area mapping and multi-ATR imaging
  • Dynamic Imaging with Rapid Scan and Step-Scan options
  • Multivariate analysis PCA

IRT-7100: Fully Automated FTIR Microscope

The IRT-7100 fully automated FTIR microscope includes a standard single-point mid-band MCT detector, with the option to simultaneously install up to two detectors. It is easily field-upgradable to an IR imaging system by adding an optional 16-channel linear array detector. The standard automatic sample stage and “IQ Mapping” function provides wide area mapping and multi-ATR mapping.

  • Fully automated sample stage with autofocus function as standard
  • IQ Mapping
  • Multiple objective capabilities with a 4-position objective carousel
  • Dual detector capability (optional second detector and optional user-swappable detectors)
  • Field upgrade to high-speed IR Imaging System using a 16-element linear array detector

IRT-7200 Linear Array FTIR Imaging Microscope

The IRT-7200 Linear Array FTIR Imaging microscope includes two detectors as standard: a 16-channel linear array detector and a single-point mid-band MCT detector. The combination of the standard automatic sample stage and “IQ Mapping” function allows mapping analyses of a larger sample area, multi-area ATR mapping, and IR imaging of a specified area with extremely high spatial resolution and excellent sensitivity in a short time.

  • Full high-speed IR Imaging function using a 16-element linear array detector
  • IQ Mapping
  • Multiple objective capabilities with a 4-position objective carousel
  • Wide area mapping and multi-ATR imaging
  • Dynamic Imaging with FTIR step-scan option
  • Multivariate analysis Principal Component Analysis (PCA) as standard

Spectra Manager Imaging Suite – Micro Analysis Measurement Program

Spectra Manager™ provides automatic functions and simplified operations to minimize manual operation. Measurement conditions, microscope sample monitoring/control and measurement results can be viewed on a single screen. The microscope control interface includes various types of measurements such as single and multi-point, mapping, and linear array measurements using a single mouse-click for mode selection. Real-time monitoring of the spectrum and a calculated chemical image can be specified during the mapping measurement.

Innovative ATR Mapping with Clear View and IQ Mapping

The Clear-View ATR objectives enable simultaneous sample viewing while preparing for ATR measurement and as the ATR crystal element contacts the sample. IQ Mapping can be used for automatic multi-point mapping, line mapping, grid mapping and IR Imaging analysis of a microscopic area even with a manual sample stage and a single-element detector.

IQ Mapping coupled with a Clear-View ATR objective allows ATR mapping and ATR Imaging of any sample in contact with the ATR objective without moving the sample stage or ATR objective while observing the entire area of the sample in contact with the crystal. This provides high-speed and cross-contaminant-free measurements of a small sampling area.

Full-Vacuum System

For FTIR measurement, absorption peaks due to atmospheric water vapor and CO2 can make it difficult to obtain high-quality sample spectra. The most effective solution to this problem is the measurement of samples in a vacuum. As a factory option, a vacuum-type FTIR microscope system can be provided.