FT/IR 4X

Standard Wavenumber Measurement Range

7,800 to 350 cm-1

FT/IR 6X

Standard Wavenumber Measurement Range

7,800 to 350 cm-1

FT/IR 8X

Standard Wavenumber Measurement Range

7,800 to 350 cm-1

Optional Extended Wavenumber Range

11,500 to 375 cm-1, 6,000 to 220 cm-1, 6,000 to 50 cm-1

Optional Extended Wavenumber Range

25000 to 20 cm-1

Optional Extended Wavenumber Range

25000 to 20 cm-1

Resolution

0.4, 0.5, 1, 2, 4, 8, 16 cm-1

Resolution

0.25, 0.5, 1.0, 2, 4, 8, 16 cm-1

Resolution

0.07, 0.25, 0.5, 1.0, 2, 4, 8, 16 cm-1

Sample Chamber

Size: 200 (W) × 260 (D) × 185 (H) mm
Optical path: Center focus, light axis 70 mm high

Sample Chamber

Size: 200 (W) × 260 (D) × 185 (H) mm
Optical path: Center focus, light axis 70 mm high

Sample Chamber

Size: 200 (W) × 260 (D) × 185 (H) mm
Optical path: Center focus, light axis 70 mm high

Interferometer

45º Michelson interferometer
Corner cube mirror interferometer, with auto-alignment
mechanism, sealed structure, DSP control

Interferometer

28º Michelson interferometer with corner-cube mirror, sealed structure (KRS-5 window, optional window is also available), auto-alignment mechanism, DSP control, aluminum mirror coating

Interferometer

28º Michelson interferometer with corner-cube mirror, sealed structure (KRS-5 window, optional window is also available), auto-alignment mechanism, DSP control, aluminum mirror coating

Mirror Coating

Aluminum (Al)

Mirror Coating

Aluminum (Al)

Mirror Coating

Gold (Au)

N2 Purge and Vacuum

Sample/Detector Compartment

Interferometer (Optional)

N/A

N2 Purge and Vacuum

Sample/Detector Compartment

Interferometer

Full Vacuum (Optional)

N2 Purge and Vcuum

Sample/Detector Compartment

Interferometer

Full Vacuum (Optional)

Drive Method

Mechanical bearing,
electromagnetic drive

Drive Method

Mechanical bearing,
electromagnetic drive

Drive Method

Mechanical bearing,
electromagnetic drive

Rapid Scan

80 spectra/sec (16 cm-1 resolution)

Rapid Scan

40 spectra/sec. (16 cm-1 resolution)

Rapid Scan

40 spectra/sec. (16 cm-1 resolution)

Step Scan

N/A

Step Scan

N/A

Step Scan

5 msec (optional: 10 nsec)

Beam Splitter

Standard: Ge/KBr
Option: Si/CaF2, Ge/CsI (not interchangeable)

Beam Splitter

Standard: Ge/KBr
Option: Broad band Quartz, Si/CaF2, Broad band KBr, Broad band mylar, Mid-far IR broad band, (exchangeable, optional automatic beam splitter changer is available)

Beam Splitter

Standard: Ge/KBr
Option: Broad band Quartz, Si/CaF2, Broad band KBr, Broad band mylar, Mid-far IR broad band, (exchangeable, optional automatic beam splitter changer is available)

Light Source

Standard: High-intensity ceramic source
Option: Halogen lamp (factory option only)

Light Source

Standard: High-intensity ceramic source
Option: Halogen lamp (factory option only)

Light Source

Standard: High-intensity ceramic source
Option: Halogen lamp (factory option only)

Detector

DLaTGS (with Peltier temperature control) (standard)

Detector

DLaTGS (with Peltier temperature control) (standard)

Detector

DLaTGS (with Peltier temperature control) (standard)

Optional Detectors

W-MCT, M-MCT, N-MCT, Si, InSb, InGaAs (optional)
Up to two detectors can be installed.

Optional Detectors

MCT-N, MCT-M, MCT-W, MCT-PV, Si photodiode (visible, near IR), InSb, InGaAs, DLATGS (PE window), Broadband DLATGS, Si bolometer, and DLATGS (for micro measurement). Up to 2 detectors can be mounted inside the main unit, and the external detector unit should be applied if more than 3 detectors are used (PC switching). There are some limited detectors for mounting inside the main unit, and up to 2 detectors can be mounted to the external detector unit.

Optional Detectors

MCT-N, MCT-M, MCT-W, MCT-PV, Si photodiode (visible, near IR), InSb, InGaAs, DLATGS (PE window), Broad band DLATGS, Si bolometer, and DLATGS (for micro measurement). Up to 2 detectors can be mounted inside the main unit, and the external detector unit should be applied if more than 3 detectors are used (PC switching). There are some limited detectors for mounting inside the main unit, and up to 2 detectors can be mounted to the external detector unit.

Signal-to-Noise Ratio:
(4 cm-1, 1 min, near 2,200 cm-1)

35,000:1

Signal-to-Noise Ratio:
(4 cm-1, 1 min, near 2,200 cm-1)

47,000:1

Signal-to-Noise Ratio:
(4 cm-1, 1 min, near 2,200 cm-1)

55,000:1

Gain Switching

Auto, 1, 2, 4, 8, 16, 32, 64, 128

Gain Switching

Auto, 1, 2, 4, 8, 16, 32, 64, 128

Gain Switching

Auto, 1, 2, 4, 8, 16, 32, 64, 128

Communication

USB 2.0

Communication

USB 2.0

Communication

USB 2.0

Dimensions and Weight

FT/IR-4X Model:
386 (W) × 479 (D) × 254 (H) mm, 18 kg

Dimensions and Weight

FT/IR-6X Purge Model:
600 (W) × 690 (D) × 315 (H) mm, 56 kg
FT/IR-6X V Interferometer Vacuum Model:
600 (W) × 690 (D) × 315 (H) mm, 58 kg
FT/IR-6X FV Full Vacuum Model:
600 (W) × 700 (D) × 355 (H) mm, 70 kg

Dimensions and Weight

FT/IR-8X Purge Model:
600 (W) × 690 (D) × 315 (H) mm, 56 kg
FT/IR-8X V Interferometer Vacuum Model:
600 (W) × 690 (D) × 315 (H) mm, 58 kg
FT/IR-8X FV Full Vacuum Model:
600 (W) × 700 (D) × 355 (H) mm, 70 kg
Power supply unit:
85 (W) × 260 (D) × 197 (H) mm, 4.7 kg

Standard Composition

ItemQuantityDescription
AC Cable1AC cable for the power supply
USB Cable1Cable connecting the main unit to the PC
Sample Holder1
Standard Sample1Polystyrene film
Stepped Pin2Used for locating optional accessories in the sample compartment
Instruction Manual1
Installation Image1Spectra Manager™ and KnowItAll® JASCO Edition
Fuses2
* LE or LE-CFR Models do not include  KnowItAll® JASCO Edition.