FT/IR-4X Spectrometer
The FT/IR-4X is a powerful Mid-IR FTIR spectrometer with many features that you find in a research grade instrument, such as non-hygroscopic KRS-5 windows to prevent damage to the interferometer, a temperature controlled DLaTGS detector, and a high output ceramic source for maximum sensitivity. Permanent optical alignment is guaranteed by corner cube (retro-reflective) mirrors with auto-alignment for maximum energy.
Wavenumber range: 7,800 to 350 cm-1
Resolution: 0.4 cm-1
S/N ratio: >35,000:1
System Features
-
IQX accessory recognition
-
Vibration-proof optical bench
-
Wavenumber range with standard DLaTGS detector 7,800 to 350 cm-1
-
NIR and Far IR options with fixed broad-band beam splitter and two detectors
-
Built-in automated validation with NIST traceable polystyrene and glass filters
-
Corner-cube (retro-reflective) mirrors with automatic energy alignment
-
Purgeable sample compartment and detector housing (interferometer as option)
-
Up to 80 Hz Rapid Scan with interval scan for fast kinetic measurement
-
Optional 21 CFR part 11, IQ, OQ, and GxP compliance
-
Spectra Manager™ User Adaptive Software
Accessories
-
Large sample compartment
-
For flexible applications, a second detector can be added, such as an MCT or InGaAs, with automatic exchange and dedicated options to work from the near- to mid-IR and from the mid- to far-IR.
-
Options for FTIR microscopy and IR Imaging
-
NIR, mid-IR and far-IR wavenumber extension
-
Integrated ATR PRO ONE 4X with a choice of prisms including a high throughput monolithic diamond, germanium, or zinc selenide.
Peer-Reviewed Articles
Applications
-
Application
FT-NIR Measurement of the Iodine Value in Fat
Figure 1. FT-NIR system with thermostated cell holder for Iodine value (IV) measurement The Iodine Value (IV) is used as an index for the degree of unsaturation in fats, and is used for evaluating the nature of fatty oils and bio-diesels. The iodine value is typically measured using a wet chemistry method as described in the standard methods of AST...
-
Application
FTIR Analysis of Foreign Material using View-Through ATR
ATR PRO ONE VIEW There are various FTIR methods that can be used to identify foreign material or contaminants. FTIR microscopy is used for foreign material where the size is in the order of few microns, but when a sample with foreign material can be observed by the naked eye, the particle typically is typically greater than several hundred microns ...
-
Application
Quantification of Ethanol in Ethanol-based antiseptics
Figure 1. FT/IR-4600 and ATR PRO ONE When used in infectious disease control, the ethanol concentration in ethanol-based antiseptics used for hand sterilization should be between 70 and 83 percent by volume (vol%). Recently, as a temporary measure against the novel coronavirus, the use of 60 vol% has been allowed when ethanol is difficult to obtain...