Fluorescence Temperature Control
Single Position Cell Holders
![Fluorescence Temperature Control](https://jascoinc.com/wp-content/uploads/2017/05/EHC-813-480x284.png)
EHC-113 | Peltier Thermostatted (Air-Cooled) Cell Holder with Stirrer
The EHC-813 cell holder is an air-cooled accessory for temperature control (without the need for a water circulator) to vary the sample temperature between 10 to 60ºC at 25ºC. The cell holder includes a stirrer for uniform cell temperature and can be used with microcells (3 x 3 mm or 5 x 5 mm) as well as standard 10 x 10 mm path length cells.
![ETC-115|Water-cooled Peltier Thermostatted Cell Holder with Stirrer](https://jascoinc.com/wp-content/uploads/2017/05/ETC-815-480x291.png)
ETC-115 | Peltier Thermostatted (Water-Cooled) Cell Holder with Stirrer
Used with a temperature controlled circulating water bath (not supplied) to vary the sample temperature from -10 to 110ºC. The temperature of the sample can be monitored in the holder or by inserting a temperature probe into the sample cuvette and a magnetic stirrer is included to maintain temperature equilibrium in the cell. The cell holder can be used with microcells (3 x 3 mm or 5 x 5 mm) as well as standard 10 x 10 mm path length cells.
![STR-112 Powder Sample Cell Holder](https://jascoinc.com/wp-content/uploads/2017/05/STR-811-480x313.png)
STR-112 | Water Thermostatted Cell Holders
Used with a temperature controlled circulating water bath (not supplied) to maintain a constant sample temperature from 5 to 90ºC. A magnetic stirrer is included to maintain temperature equilibrium in the cell. Can be used with microcells (3 x 3 mm or 5 x 5 mm) as well as standard 10 x 10 mm path length cells.
![CTH-807 Water Thermostatted Cell Holder](https://jascoinc.com/wp-content/uploads/2017/05/P15-CTH-807-480x429.png)
CTH-107 | Water Thermostatted Cell Holder
A simple water circulated cell holder for 10 x 10 mm cuvettes. A thermostatted circulator is required.
Multi-Position Cell Changers
![FCT-116S Water Thermostatted Automatic 4-Position Turret Cell Changer with Stirrer](https://jascoinc.com/wp-content/uploads/2017/05/FCT-816S-480x340.png)
FCT-116/116S | Water Thermostatted Automatic 4-Position Turret Cell Changers
FCT-117/FCT-117(S) | Water Thermostatted Automatic 8-Position Turret Cell Changers
Automatic 4- and 8- position cell changers. Used with a temperature controlled circulating water bath (not supplied) to maintain a constant sample temperature from 5 to 90ºC. A magnetic stirrer is included in the ‘S’ type to maintain temperature equilibrium in the cell. The cell holder accepts microcells (3 x 3 mm or 5 x 5 mm) as well as standard 10 x 10 mm path length cells.
![PTC-118 Water-cooled Peltier Thermostatted 4-Position Automatic Cell Changer with Stirrer](https://jascoinc.com/wp-content/uploads/2017/05/PCT-818-480x323.png)
PTC-118 | Peltier Thermostatted (Water-Cooled) 4-Position Automatic Cell Changer with Stirrer
Used with a temperature controlled circulating water bath (not supplied) to vary the sample temperature from -10 to 110ºC. The temperature of the sample can be monitored by the holder or by inserting a temperature probe into the sample solution and a magnetic stirrer can be included to maintain temperature equilibrium in the cell. The cell holder accommodates microcells (3 x 3 mm or 5 x 5 mm) as well as standard 10 x 10 mm path length cells. For use with the FP-8350, 8550, or 8650.
Other Temperature Control Accessories
![CSP-129 Sample Compartment Lid with Syringe Port](https://jascoinc.com/wp-content/uploads/2017/05/CSP-829-480x457.png)
CSP-129 | Sample Compartment Lid with Syringe Port
For fast reactions the addition of a reagent can be made into to the sample cell without opening and closing the sample compartment lid. It is recommended for use with cell holders that include an integrated stirrer, such as the STR-112, EHC-113, or ETC-115 cell holders and is compatible with a 2 inch (50 mm) syringe needle.
![MCB-100 Mini Water Circulation Bath](https://jascoinc.com/wp-content/uploads/2017/05/MCB-100-344x480.png)
MCB-100 | Mini Water Circulation Bath
Small (160W x 263H x 225D mm) circulation bath (reservoir volume 200 mL). Maintains a constant temperature from ambient temperature – 10ºC to 40ºC (with a temperature sensor accuracy of 0.2ºC at 20ºC).
![HPC-136 High Temperature Powder Cell Unit](https://jascoinc.com/wp-content/uploads/2017/05/HPC-836-480x376.png)
HPC-136 | High Temperature Powder Cell Unit
Used to measure the effects of temperature variation on the powder sample fluorescence intensity. Temperature control ranges from room temperature to 300ºC.
![CSH-131 Cyrostat Holder](https://jascoinc.com/wp-content/uploads/2017/05/CSH-831-480x388.png)
CSH-131 | Cyrostat Holder
Used with Oxford Instrument’s Optistat-DN/DN2/DN-V/DN-V2 cyrostats for low temperature sample measurement.