ATR Accessory Attenuated Total Reflectance

An ATR accessory is one of the most practical choices for sample measurement. In most cases there is very little requirement for sample preparation. The ATR Pro One and ATR Pro One View are the ‘signature’ single reflection monolithic diamond models with wide spectral range and high optical throughput. Versatile models include: wide range sample temperature control, polarization and environmental control.

ATR PRO ONE
Single-Reflection A

ATR PrismDiamond (High-throughput type,
Wide-band type) ZnSe, Ge
ATR/Sample Contact Area 2.5 mm diameter (ZnSe, Ge)
1.8 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence 45°
Pressure 400 kg/cm2 (ZnSe, Ge)
700 kg/cm2 (Diamond)

ATR PRO ONE VIEW
Single-Reflection ATR with Camera
Download Catalog

ATR Prism Diamond (High-throughput type and Wide-band type). ZnSe, Ge (without image)
ATR/Sample Contact Area2.5 mm diameter (ZnSe, Ge)
1.8 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence 45°
Pressur400 kg/cm2 (ZnSe, Ge)
700 kg/cm2 (Diamond
SoftwareReal-time image and recording in data file with Spectra Manager™

ATR PRO470-H
High-Pressure Single-Reflection ATR

ATR PrismDiamond
ATR/Sample Contact Area2.0 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence45°
Pressure 1,700 kg/cm2 (Diamond)

ATR PRO410-M
Multi-Reflection ATR

ATR PrismZnSe, Ge
ATR/Sample Contact Area5 x 20 mm
No. of Reflections5
Angle of incidence45°

ATR PRO450-S
Electrochemical ATR

ATR PrismDiamond, ZnSe, Ge
ATR/Sample Contact Area1.5 mm diameter
No. of Reflections1
Angle of Incidence45°
Pressure400 kg/cm2

ATR PRO550S-S, ATR PRO570S-H
Sample-Shielding Single-Reflection ATR

ATR PrismZnSe, Ge, Diamond (550S-S)
Diamond (570S-H)
ATR/Sample Contact Area1.5 mm diameter (ZnSe, Ge)
2.0 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence45°
Pressure400 kg/cm2 (550S-S)
1,700 kg/cm2 (570S-H)

ATR PRO610P-S, ATR PRO630P-H
Polarizer Single-Reflection ATR

ATR PrismZnSe, Ge, Diamond (610P-S)
Diamond (630P-H)
ATR/Sample Contact Area1.5 mm diameter (ZnSe, Ge)
2.0 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence45°
Pressure400 kg/cm2 (610P-S)
1,700 kg/cm2 (630P-H)
Polarizer/AnalyzerWire-grid polarizer (KRS-5)
Polarizer Rotation Angle0 - 360°

ATR PRO650G
65o Incident-Type Single-Reflection ATR

ATR PrismGe
ATR/Sample Contact Area3.0 mm diameter
No. of Reflections1
Angle of Incidence65°
Maximum Sample Size6 inches
* A polarizer and attenuator mesh are optional

ATR PRO670H-S, ATR PRO690H-H
Temperature Controlled Single-Reflection ATR

ATR PrismZnSe, Ge, Diamond (670H-S)
Diamond (690H-H)
ATR/Sample Contact Area1.5 mm diameter (ZnSe, Ge)
2.0 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence45°
Pressure400 kg/cm2 (670H-S)
1,700 kg/cm2 (690H-H)
Operating Temperature180°C (Diamond)
150°C (Ge)
120°C (ZnSe)
* A connector panel is required when this accessory is fitted to the FT/IR-6000FV.

ATR PRO ONE T
Large Sample Single-Reflection ATR

ATR PrismZnSe, Ge, diamond (High-throughput type, Wide-band type)
ATR/Sample Contact Area2.5 mm diameter (ZnSe, Ge)
1.8 mm diameter (Diamond)
No. of Reflections1
Angle of Incidence45°
Pressure400 kg/cm2 (ZnSe, Ge)
700 kg/cm2 (Diamond)