IRT-1000 In-Compartment FTIR Microscope

The IRT-1000 is a compact and easy to use in-compartment FTIR microscope that can be used with any FT/IR-4000 or FT/IR-6000 Series instrument. The microscope is exchanged in the same way as an ATR or transmission holder in the sample compartment, without an requirement for adjustment or optical alignment. The excellent throughput allows for highly sensitive measurements for samples as small as 20 microns. The IRT-1000 can be operated from the integrated touch panel and a PC using Spectra Manager™ Suite. Sample is observation is made with an integrated color CCD camera and a 5 inch TFT color LCD monitor and recorded using the imaging function in Spectra Manager™. JASCO’s unique ATOS (Aperture Through Optical System) provides simultaneous viewing of the sample image and sampling location specified by an aperture.
System Features
- Easy location in the sample compartment – within seconds. No optical alignment is required before measurements
- Manual stage for moving and focusing the sample measurement area
- Three measurement modes: Transmittance, Reflectance, and ATR
- DLaTGS detector in FTIR main instrument (standard)
- MCT detector or NIR optimized detector (optional)
- Optional sampling accessories for liquid and powder samples
- Unique sample observation system allows observation of the sample, even during measurements
- Measurement and processing are performed by Spectra Manager™. A video capture of the sample view is stored in the spectral data file
Options for the IRT-1000
SmartPurge™
An optional purge casing can be used to eliminate interference from atmospheric CO2 and water vapor bands. | ![]() |
ATR Objectives
There are three types of optional ATR objectives, select from:- ZnSe, Ge, or Diamond crystal prisms. An optional pressure sensor (recommended), can be used to protect the ATR objective prism. | ![]() |
Liquid Sample Holder
The liquid sample holder includes three standard spacers, 100, 50 and 25 um path lengths. | ![]() |
Powder Sample Holder
The powder sample holder can be used for diffuse reflectance measurements of samples mixed with KBr. Up to five samples can be loaded onto the holder. | ![]() |
ATR Objectives (Optional)
Model Name | ATR-1000-VZ | ATR-1000-VG | ATR-1000-VD |
---|---|---|---|
Wavelength Range (cm-1) | 4000 to 650 | 4000 to 650 | 4000 to 300 |
Objective Mirror | |||
Angle of Incidence | 40 to 53° | ||
Numerical Aperture | 0.8 | ||
Magnification | 12x | ||
Prism Material | ZnSe | Ge | Diamond |
Refractive Index | 2.4 | 4.0 | 2.4 |
Sample Area | 250 µm diameter | ||
Number of Reflections | 1 | 1 | 1 |
Objective Dimensions | 86 mm diam. x 49 mm height | ||
Weight | Approximately 430 g | ||
Recommended Pressure (Using Optional Pressure Sensor Stage) | up to 0.4 | up to 0.7 |
IRT-1000 Microscope Specifications
Measurement Method | Transmission, Reflection (standard), ATR (optional) |
Sample Observation | CCD camera (standard) |
Objective Mirror | x8 cassegrain |
Condenser Mirror | x8 cassegrain with transmission compensation |
Objective Selection | Manual exchange with no alignment required |
Detectors | Selection from available instrument detectors |
Sample Observation Area | 1.2 x 0.9 mm |
Observation Method (ATOS) | CCD camera, 5 inch LCD ATOS: Aperture Through Optical System |
Minimum Measurement Area | 20 µm2 (MCT detector) 100 µm2 (DLaTGS detector) |
Wavenumber Range | 13,000 to 300 cm2 (dependent upon FTIR configuration) |
Sample Stage | X-Y-Z manual stage |
Aperture | Independent X and Y variable aperture |
Purge | SmartPurge™ System (FT/IR-4000, 6000) |
Sample Illumination | Transmission/reflection (adjustable intensity) |
Dimensions | 144 (W) x 312 (D) x 292 (H) mm |
Weight | 7 kg |
Power Requirements | DC12V 8W (110/220 V adapter included) |